OM-2231 Page 14
802 724-A
1
115 V 10 A AC Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 3-3).
2
Circuit Breaker CB1
3
Circuit Breaker CB2
CB1 protects duplex receptacle
and 115 volts ac portion of Remote
14 receptacle from overload.
CB2 protects 24 volts ac portion of
Remote 14 receptacle from
overload.
Press button to reset breaker.
2
3
1
3-5.
Optional 115 Volts AC Duplex Receptacle And Circuit Breakers
3-6.
Electrical Service Guide
Single-Phase
Input Voltage
208
230
460
Input Amperes At Rated Output
41.2
37.3
15.5
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
60
60
25
Reference: 1997 National Electrical Code (NEC).
S-0092J
Three-Phase
Input Voltage
208
230
460
575
Input Amperes At Rated Output
33.27
30
14.79
11.72
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
50
45
20
20
Reference: 1997 National Electrical Code (NEC).
S-0092J