![Miller 907439002 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/miller/907439002/907439002_owners-manual_1796039006.webp)
EMF DATA SHEET FOR ARC WELDING POWER SOURCE
Product/Apparatus Identification
Product
Stock Number
AXCESS E 450 W/CE
907439002
AXCESS E 300 W/CE
907440002
AUTO-AXCESS E 300 ANALOG W/CE
907442002
AUTO-AXCESS E 450 ANALOG W/CE
907443002
AUTO-AXCESS E 450 DIGITAL W/CE
907496002
AUTO-AXCESS E 300 DIGITAL W/CE
907497002
Compliance Information Summary
Applicable regulation
Directive 2014/35/EU
Reference limits
Directive 2013/35/EU, Recommendation 1999/519/EC
Applicable standards
IEC 62822-1:2016, IEC 62822-2:2016
Intended use
☒
for occupational use
☐
for use by laymen
Non-thermal effects need to be considered for workplace assessment
☒
YES
☐
NO
Thermal effects need to be considered for workplace assessment
☐
YES
☒
NO
☒
Data is based on maximum power source capability (valid unless firmware/hardware is changed)
☐
Data is based on worst case setting/program (only valid until setting options/welding programs are changed)
☐
Data is based on multiple settings/programs (only valid until setting options/welding programs are changed)
Occupational exposure is below the Exposure Limit Values (ELVs)
☒
YES
☐
NO
for health effects at the standardized configurations
(if NO, specific required minimum distances apply)
Occupational exposure is below the Exposure Limit Values (ELVs)
☐
n.a
☒
YES
☐
NO
for sensory effects at the standardized configurations
(if applicable and NO, specific measures are needed)
Occupational exposure is below the Action Levels (ALs) at the
☐
n.a
☐
YES
☒
NO
standardized configurations
(if applicable and NO, specific signage is needed)
EMF Data for Non-thermal Effects
Exposure Indices (EIs) and distances to welding circuit (for each operation mode, as applicable)
Head
Trunk
Limb (hand)
Limb (thigh)
Sensory Ef
fects
Health Ef
fects
Standardized distance
10 cm
10 cm
10 cm
3 cm
3 cm
ELV EI @ standardized distance
0.17
0.14
0.23
0.13
0.30
Required minimum distance
1 cm
1 cm
1 cm
1 cm
1 cm
Distance where all occupational ELV Exposure Indices fall below 0.20 (20%)
13 cm
Distance where all general public ELV Exposure Indices fall below 1.00 (100%)
237 cm
Tested by:
Tony Samimi
Date tested:
2016-02-15
275656-A
Содержание 907439002
Страница 18: ...OM 249474 Page 12 Notes...
Страница 52: ...OM 249474 Page 46 Notes...
Страница 64: ...OM 249474 Page 58 Figure 13 2 Circuit Diagram For Axcess E 300 CE 2 Of 2...
Страница 65: ...Circuits OM 249474 Page 59 263 464 C Part 2 Of 2...
Страница 66: ...OM 249474 Page 60 Figure 13 3 Circuit Diagram For Axcess E 450 CE 1 Of 2...
Страница 67: ...Circuits OM 249474 Page 61 263 483 C Part 1 Of 2...
Страница 68: ...OM 249474 Page 62 Figure 13 4 Circuit Diagram For Axcess E 450 CE 2 Of 2...
Страница 69: ...Circuits OM 249474 Page 63 263 483 C Part 2 Of 2...
Страница 70: ...OM 249474 Page 64 Figure 13 5 Circuit Diagram For Axcess E Module...
Страница 71: ...Circuits OM 249474 Page 65 250 571 C...