General
OM-249474 Page 29
8-3. Connecting To Weld Terminals
Tools Needed:
245 733-C / 803 778-A
3/4 in. (19 mm)
4
2
3
Do not place
anything between
1
weld cable terminal
and copper bar.
!
Turn off power before connecting to
weld output terminals.
!
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your
machine.
Determine total cable length in weld circuit
(both positive and negative cables
combined) and maximum welding
amperes. See Section 8-2 to select proper
cable size.
1
Weld Output Terminal
2
Supplied Weld Output Terminal Nut
3
Weld Cable Terminal
4
Copper Bar
Remove supplied nut from weld output
terminal. Slide weld cable terminal onto
weld output terminal and secure with nut so
that weld cable terminal is tight against
copper bar.
Do not place anything
between weld cable terminal and copper
bar. Make sure that the surfaces of the
weld cable terminal and copper bar are
clean.
Correct Installation
Incorrect Installation
Содержание 907439002
Страница 18: ...OM 249474 Page 12 Notes...
Страница 52: ...OM 249474 Page 46 Notes...
Страница 64: ...OM 249474 Page 58 Figure 13 2 Circuit Diagram For Axcess E 300 CE 2 Of 2...
Страница 65: ...Circuits OM 249474 Page 59 263 464 C Part 2 Of 2...
Страница 66: ...OM 249474 Page 60 Figure 13 3 Circuit Diagram For Axcess E 450 CE 1 Of 2...
Страница 67: ...Circuits OM 249474 Page 61 263 483 C Part 1 Of 2...
Страница 68: ...OM 249474 Page 62 Figure 13 4 Circuit Diagram For Axcess E 450 CE 2 Of 2...
Страница 69: ...Circuits OM 249474 Page 63 263 483 C Part 2 Of 2...
Страница 70: ...OM 249474 Page 64 Figure 13 5 Circuit Diagram For Axcess E Module...
Страница 71: ...Circuits OM 249474 Page 65 250 571 C...