OM-249474 Page 28
SECTION 8
−
RECOMMENDED SETUP PROCEDURES
8-1. Weld Output Terminals
!
Turn off power before connecting
to weld output terminals.
!
Do not use worn, damaged, un-
dersized, or repaired cables.
1
Positive (+) Weld Output Terminal
2
Negative (
−
) Weld Output Terminal
.
For welding output terminal connec-
tions see Sections 7-2 and 8-3 for
typical connection processes.
output term1 2015
−
02 / Ref. 245 746-B
1
2
8-2. Selecting Weld Cable Sizes*
NOTICE
−
The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is
100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable
size.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
100 ft (30 m) or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10
−
60%
Duty
Cycle
AWG (mm
2
)
60
−
100%
Duty Cycle
AWG (mm
2
)
10
−
100% Duty Cycle
AWG (mm
2
)
100
4 (20)
4 (20)
4 (20)
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
150
3 (30)
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
200
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
4/0 (120)
250
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x2/0 (2x70)
300
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x3/0 (2x95)
350
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x3/0 (2x95)
2x4/0 (2x120)
400
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x4/0 (2x120) 2x4/0 (2x120)
500
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x4/0 (2x120)
3x3/0 (3x95)
3x3/0 (3x95)
600
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x4/0 (2x120)
3x3/0 (3x95)
3x4/0 (3x120) 3x4/0 (3x120)
700
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x4/0 (2x120)
3x3/0 (3x95)
3x4/0 (3x120) 3x4/0 (3x120) 4x4/0 (4x120)
800
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x4/0 (2x120)
3x4/0 (3x120) 3x4/0 (3x120) 4x4/0 (4x120) 4x4/0 (4x120)
*
This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm
2
for metric use
***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart).
Ref. S-0007-L 2015
−
02
.
In pulse welding applications using inverter power sources, peak currents can result in extreme voltage drops producing poor welding characteris-
tics with undersized cables. A recommendation for weld cable size is a minimum of 2/0 for 300 ampere welding power sources and 4/0 for 450
ampere welding power sources when total cable length is less than 100 ft (30m).
Содержание 907439002
Страница 18: ...OM 249474 Page 12 Notes...
Страница 52: ...OM 249474 Page 46 Notes...
Страница 64: ...OM 249474 Page 58 Figure 13 2 Circuit Diagram For Axcess E 300 CE 2 Of 2...
Страница 65: ...Circuits OM 249474 Page 59 263 464 C Part 2 Of 2...
Страница 66: ...OM 249474 Page 60 Figure 13 3 Circuit Diagram For Axcess E 450 CE 1 Of 2...
Страница 67: ...Circuits OM 249474 Page 61 263 483 C Part 1 Of 2...
Страница 68: ...OM 249474 Page 62 Figure 13 4 Circuit Diagram For Axcess E 450 CE 2 Of 2...
Страница 69: ...Circuits OM 249474 Page 63 263 483 C Part 2 Of 2...
Страница 70: ...OM 249474 Page 64 Figure 13 5 Circuit Diagram For Axcess E Module...
Страница 71: ...Circuits OM 249474 Page 65 250 571 C...