Trouble
OM-249474 Page 53
C. General Purpose LEDs
D17
On
Gnd Cnt
−
Indicates ground error. Contact nearest factory Authorized Service Agent.
Off
Indicates no error
D25
On
OVR CNT
−
Indicates an error. Contact nearest factory Authorized Service Agent.
Off
Indicates no error
D26
On
OVR PWR
−
Indicates unit is operating at max input current. Contact nearest factory Authorized Service
Agent.
Off
Indicates no error
D28
— —
Future use
— —
D30
On
OVR TMP
−
Indicates unit is overheated. Turn unit off and allow to cool. If error continues, contact nearest
factory Authorized Service Agent.
Off
Indicates no error
D33
On
Contactor
−
Indicates unit is receiving a contactor On signal
Off
Indicates contactor on signal is not being received. Check input connections.
D43
On
ARM/O
−
Ind10 VDC is present, should flash at same rate as ARM AWAKE
Off
Ind10 VDC is not present
D44
On
E-Stop
−
Indicates E-Stop is not present
Off
Indicates E-Stop has been engaged, check external sources
D98
On
USB Host on
−
Indicates this function is operating properly
Off
Indicates USB error. Cycle unit power, if error is still present contact nearest factory Authorized Service
Agent
D101
On
Ind2.5 VDC is present
Off
Ind2.5 VDC is not present
D108
On
Ind25 VDC is present
Off
Ind25 VDC is not present
Содержание 907439002
Страница 18: ...OM 249474 Page 12 Notes...
Страница 52: ...OM 249474 Page 46 Notes...
Страница 64: ...OM 249474 Page 58 Figure 13 2 Circuit Diagram For Axcess E 300 CE 2 Of 2...
Страница 65: ...Circuits OM 249474 Page 59 263 464 C Part 2 Of 2...
Страница 66: ...OM 249474 Page 60 Figure 13 3 Circuit Diagram For Axcess E 450 CE 1 Of 2...
Страница 67: ...Circuits OM 249474 Page 61 263 483 C Part 1 Of 2...
Страница 68: ...OM 249474 Page 62 Figure 13 4 Circuit Diagram For Axcess E 450 CE 2 Of 2...
Страница 69: ...Circuits OM 249474 Page 63 263 483 C Part 2 Of 2...
Страница 70: ...OM 249474 Page 64 Figure 13 5 Circuit Diagram For Axcess E Module...
Страница 71: ...Circuits OM 249474 Page 65 250 571 C...