OM-287348 Page 28
Trigger Parameter Settings (Continued)
1
Trigger Mode Soft Key
2
Parameter Settings Soft Key
Press key to enter the trigger parameter set-
tings.
3
Ampere/WFS Control Knob
Use knob to adjust parameter value.
4
Sequence Parameter Scroll Soft Key
Press key to scroll through sequence param-
eter.
5
Home Screen Soft Key
Press key to return to home screen.
While in Pulsed MIG mode, press parameter
settings soft key to enter the trigger parame-
ter settings. Use knob to adjust parameter
value. Use sequence parameter soft key to
scroll through sequencer. The following
parameters will be displayed.
6
Gas Pre-flow LED
Use control to set length of time gas flows be-
fore arc initiation. (Min= 0.1s, max= 2.0s).
7
Wire Run-In LED
Use control to set the percentage of selected
wire speed before arc starting. (Min= 15%,
max= 125%).
8
Slope Down Time
Use control to select amount of time that it
takes to slope up/down from weld amperage
to final amperage. To disable, set to 0. (Min=
0.1s, max= 10s).
9
Gas Post-flow LED
Use control to set length of time gas flows af-
ter welding stops to protect weld puddle.
(Min= 0.1s, max= 15s).
10 Wire Burn-back Time LED
Use control to select time that welding wire
stays energized after trigger is released.
(Min= 5%, max= 200%).
11 Initial Current LED
Use control to set the percentage of the
welding current to set at initial level. (Min=
10% max= 100%).
12 Final Current LED