OM-1085 Page 13
E. Remote Center Position Control
If multiple Center Position remote controls are desired, they must be switched
using relays with gold alloy cross bar type contacts or equivalent.
NOTE
Remove jumper links between
1T15 and 1T16, and 2T47 and
2T48.
Connect leads from remote control
to 1T15, 2T48, and 2T55.
Rear
55
15
48
F. Remote Speed To Left Control
If multiple remote speed controls (more than one of either left or right) are desired,
an optional multi-pass circuit board must be installed.
NOTE
Remove jumper link between 1T8
and 1T53.
Connect leads from remote control
to 1T46 and 1T53.
Rear
53
46
G. Remote Speed To Right Control
If multiple remote speed controls (more than one of either left or right) are desired,
an optional multi-pass circuit board must be installed.
NOTE
Remove jumper link between 1T3
and 1T54.
Connect leads from remote control
to 1T45 and 1T54.
Rear
54
45