OM-350 Page 19
3-4.
Amperage Controls
1
Amperage Adjustment Control
Use control to select weld output
amperage.
2
Amperage Control Switch
Use switch to select way of control-
ling amperage adjustment.
For front panel control, place switch
in the Panel position.
For remote control, place switch in
Remote 14 position (see Section
2-13).
3
Fingertip Control
4
Remote Hand Control
5
Remote Foot Control
See example below.
1
Set Switch
Adjust Remote Control
Set Desired Maximum Amperage
3
4
5
2
Example Of Front Panel Amperage Control
In Example:
Min = 25 A AC
Max = 300 A AC
3-5.
Start Amperage Controls
1
Start Switch
On – provides start amperage
control;
Off – no start amperage control.
2
Start Amperage Control
Use control to select amperage lev-
el for arc starting that is different
than Amperage Adjustment control
setting.
The numbers are a percentage of
the maximum welding amperage of
the unit and not an actual value.
1
2