OM-229 253 Page 24
4-12. Remote 14 Receptacle And Terminal Strip 1T Information
Socket
Terminal
Information
24 VOLTS AC
A
A
24 volts AC. Protected by circuit breaker CB2.
B
B
Contact closure to A completes 24 volts AC contactor control circuit.
REMOTE OUTPUT CONTROL
C
C
Command reference; 0 to +10 volts DC (CC), +10 volts DC (CV).
D
D
Remote control circuit common.
E
E
0 to +10 volts DC input command signal from remote control.
F
*
Current feedback; 0 to +10 volts DC, 1 volt per 100 amperes.
H
*
Voltage feedback; 0 to +10 volts DC, 1 volt per 10 arc volts.
115 VOLTS AC
I
I
115 volts, 15 amperes, 60 Hz DC. Protected by circuit breaker CB1.
J
J
Contact closure to I completes 115 volts AC contactor control circuit.
GND
K
G
K
*
Chassis common.
Circuit common for 24 and 115 volts AC circuits.
REMOTE POWER ON/OFF
*
L
To remote On/Off switch.
*
M
REMOTE VOLTAGE SENSING
N
N
Voltage sensing signal from Negative (
−
) weld output terminal.
*
P
Voltage sensing signal from Positive (+) weld output terminal.
* Not Used