OM-225 757 Page 16
3-9. Remote 14 Receptacle Information
Socket*
Socket Information
24 VOLTS AC
A
24 volts AC. Protected by circuit breaker CB1.
B
Contact closure to A completes 24 volts AC contactor control circuit.
REMOTE
OUTPUT
CONTROL
C
Output to remote control; +10 volts DC in MIG mode.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from remote control.
M
CC/CV select
A/V
AMPERAGE
VOLTAGE
F
Current feedback; +1 volt DC per 100 amperes.
H
Voltage feedback; +1 volt DC per 10 arc volts.
GND
G
Circuit common for 24 volts AC circuit.
*The remaining sockets are not used.
3-10. Connecting Remote Control
Ref. S-0004-A / S-0750
!
Turn off power before
connecting to Remote 14
receptacle.
1
Remote 14 Receptacle RC14
Connect remote control to RC14.
A
J
B
K
I
C L N
H
D M
G
E
F
1
OR
OR
3-11. Remote 10 Receptacle Functions For Spoolmatic 15A/30A
Socket
Socket Information
B, C
Motor control voltage to spool gun motor.
D, G
Trigger closure.
E
Wire feed speed command reference; +8 volts DC.
F
Wire feed speed command signal.
H
Connects motor speed control counterclockwise to circuit
common through a small resistance allowing motor to run at
0 setting of motor speed control.
.
See spool gun Owner’s Manual for spool gun operation.
Содержание SHOPMATE 300 DX
Страница 4: ......
Страница 14: ...OM 225 757 Page 10...
Страница 28: ...OM 225 757 Page 24 SECTION 6 ELECTRICAL DIAGRAM Figure 6 1 Circuit Diagram...
Страница 29: ...OM 225 757 Page 25 242 567 a...
Страница 30: ...Notes...