OM-293 Page 12
2-7.
Remote 14 Receptacle Information
A
J
K
I
Socket*
Socket Information
B
K
I
C
L
N
H
D
M
G
24 VOLTS AC
A
24 volts ac. Protected by circuit breaker CB2.
E
F
24 VOLTS AC
B
Contact closure to A completes 24 volts ac con-
tactor control circuit.
115 VOLTS AC
I
115 volts ac. Protected by circuit breaker CB1.
115 VOLTS AC
J
Contact closure to I completes 115 volts ac con-
tactor control circuit.
G
Circuit common for 24 and 115 volts ac circuits.
Ref. 121 470-E / Ref. 192 412
GND
K
Chassis common.
*The remaining sockets are not used.
2-8.
Electrical Service Guide
Input Voltage
200
230
460
Input Amperes At Rated Output
46
40
20
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay
2
50
50
25
Normal Operating 3
70
60
30
Min Input Conductor Size In AWG/Kcmil
8
8
12
Max Recommended Input Conductor Length In Feet (Meters)
89
(27)
118
(36)
188
(57)
Min Grounding Conductor Size In AWG/Kcmil
8
10
12
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).