OM-222 166 Page 45
S
OPEN
−
no cable or plug in place
ClntFR
−
This is the coolant flow rate (in GPM) from the cooler on a liquid-cooled system.
ClrSts
−
This is the status of the cooler. Possible labels:
S
Off
S
Flowing
The second diagnostic screen is available by again pressing and holding the Run Status
button and pressing the Parameters
Hz
V
A
kW
button.
VLnA
−
B: 460V Therm1: 75 DIAG2
VLnB
−
C: 460V Therm2: 75 Therm5: OPEN
VLnC
−
A: 460V Therm3: 75 ClrTmp: 77
VBus: 650V Therm4: OPEN RmtFlw: Off
System Diagnostic Screen
VLnA-B
−
This is the phase to phase line voltage between phases A and B.
VLnB-C
−
This is the phase to phase line voltage between phases B and C.
VLnC-A
−
This is the phase to phase line voltage between phases C and A.
VBus
−
This is the DC bus voltage.
Therm1
−
This is the temperature of the current source primary heatsink.
Therm2
−
This is the temperature of the bridge heatsink.
Therm3
−
This the the temperature of the current source secondary heatsink.
Therm4
−
Open (not used).
Therm5
−
Open (not used).
ClrTmp
−
This is the temperature of the coolant on a liquid-cooled system.
S
OPEN
−
no cooler is detected.
RmtFlw
−
This is the status of the relay contacts for remote coolant flow on a liquid-cooled system.
S
OFF
S
ON
.
RmtFlw feature is unsupported on the current platform.