OM-222 166 Page 33
Mode....: Manual Power..: 0.0 KW
Command.: 0.0 KW Current: 0 A
Run Time: 00:03:00 Voltage: 0 V
Frequency: 4.5 KHz
Manual Program Screen
The only programmable selections are Command power and Run Time. Command can be adjusted to deliver up to 35 KW (based on maximum
power selected in the set-up screen) for a period of up to 99 hours, 59 minutes, 59 seconds.
Power source operating power, current, voltage, and frequency are shown on the right-hand side of the display.
To reset the system back to factory default settings, turn off the power source, and wait until the display goes blank. Turn on the power source. When
the display lights, press and hold the Increase
and Decrease
buttons. A message will display Press Program to reset factory
defaults. Release the Increase
and Decrease
buttons, and press the Program
button.
6-5. Run Status
Run status allows the operator to check status of a program during in-process heating. Depending on the control mode (Temperature or Manual) and
the temperature based mode (Preheat, Bake-Out, PWHT, or Custom), different style screens appear on the display. Run status is for monitoring
purposes only and has no selectable or changeable parameters.
6-5-1.
Temperature Based Control
6-5-1-1. Preheat, Bake-Out And PWHT Run Status Screen
Mode.......: Preheat TC5: 77
Target Temp:
−−−−
TC6: 77
Countdown..:
−−
:
−−
:
−−
Status.....: Stopped
Run Status Screen
Mode displays the programming mode (Preheat, Bake-Out, PWHT, or Custom Program). During active operation, Target Temp shows the target
temperature based on the specific program, Countdown shows the time remaining in a soak segment, and Status shows the program segment type
(step, soak, ramp, hold, or stopped). TC5 and TC6 display the temperature of thermocouples 5 and 6. This screen is for monitoring purposes only.
6-5-1-2. Custom Program
Mode.......: Custom Program TC5: 77
Target Temp:
−−−−
TC6: 77
Countdown..:
−−
:
−−
:
−−
Segment: 1
Status.....: Stopped
Run Status Screen
During active operation, Target Temp shows the target temperature based on the active segment, Countdown shows the time remaining in a soak
segment, and Status shows the program segment type (step, soak, ramp, hold, or stopped) of the active segment and the active segment number.
TC5 and TC6 display the temperature of thermocouples 5 and 6. This screen is for monitoring purposes only.