OM-222 166 Page 25
Possible selections:
Degree Units:
°
F /
°
C
Tolerance:
±
5 to 99 in
°
F (
±
3 to 55 in
°
C)
Backlight: Yes / No
Input Type: K TC
Control Mode: Temp / Time / Manual
Power Output: 1 to 35
System Lock: Yes / No
Degree Units
−
press the Increase
or Decrease
buttons to select temperature units. Selection will
drive the
°
F /
°
C indicator LED’s.
S
The factory default is
°
F.
S
Changing from
°
F to
°
C will convert stored program values: ramp temperature, soak temperature, ramp rate,
and temperature tolerance.
Tolerance
−
press the Increase
or Decrease
button to select the desired temperature tolerance.
S
The factory default is
±
25
°
F.
Backlight
−
press the Increase
or Decrease
button to turn LCD display backlight On or Off.
S
The factory default is On.
Input Type
−
press the Increase
or Decrease
button to select the desired temperature input
device.
S
The factory default and only selection is K TC.
Control Mode
−
press the Increase
or Decrease
button to select the desired method of system
control, either Temperature or Manual. For more details about methods of control, see Section
6-4.
S
The factory default is temperature based control.
Power Outpu
t
−
press the Increase
or Decrease
button to adjust the maximum power source
output.
S
The factory default is 35 kW.
System Lock
−
press the Increase
or Decrease
button to lock or unlock the operator interface to
prevent tampering with any programs. Yes indicates the system is locked, and No indicates the
system is unlocked.
S
The factory default is No (unlocked).
.
All parameters in System Setup are considered global, and any changes to the system set-up parameters will apply to all programs.
Содержание ProHeat 35