4-12. Secondary Insulation Protection
Secondary insulation protection
circuitry automatically shuts down
the power source output if a
potentially hazardous condition
exists at the heating device
connected to the power source (e.g.
insulation has broken down on a
heating blanket causing the
conductor to come into contact with
the workpiece or a heating coil
touches the workpiece causing a
short in the output circuit).
The supplied ground lead(s) must
be connected between the
workpiece and power source to
provide proper secondary insula-
tion protection from a short in the
output circuit.
For single output, only one
ground lead is required. For dual
output , use both ground leads.
1
Receptacles
2
Plug
To connect plug, align key with key-
way, insert end into receptacle, and
rotate plug until tight.
3
Handle
4
Magnet
.
The secondary isolation magnet
must be in contact with bare
metal (free from rust, paint,
grease, etc.).
5
Workpiece
Use handle to place magnet on the
workpiece.
3
4
5
1
2