OM-193 267 Page 29
Program 3
−−
.052 ER70S
−
3 Mild Steel
−−
Recommended Gases: Argon/CO
2
Gases: Argon/CO
2
mixes up to 10% CO
2
;
Argon/O
2
mixes up to 5% O
2
IPM
Trim
Peak Amp
Background Amp
Freq.
Pulse Width
Starting Amps
70
0
369
44
57
2.30
600
138
10
449
68
94
2.43
600
206
20
484
89
125
2.58
624
274
30
512
117
150
2.70
652
342
40
538
138
170
2.80
674
410
50
562
162
191
2.90
698
478
60
574
174
212
3.00
727
546
70
585
185
235
3.10
755
614
80
595
195
248
3.15
780
682
90
600
200
253
3.18
801
750
100
600
204
256
3.20
801
Program 4
−−
.062 ER70S
−
3 Mild Steel
−−
Recommended Gases: Argon/CO
2
Gases: Argon/CO
2
mixes up to 10% CO
2
;
Argon/O
2
mixes up to 5% O
2
IPM
Trim
Peak Amp
Background Amp
Freq.
Pulse Width
Starting Amps
60
0
458
51
60
2.42
674
94
10
489
82
81
2.62
688
128
20
512
110
102
2.80
702
162
30
527
134
120
2.92
716
196
40
541
155
138
3.04
730
230
50
557
176
156
3.17
748
264
60
569
197
174
3.30
762
298
70
581
218
192
3.43
776
332
80
590
240
210
3.56
790
366
90
600
251
220
3.62
801
400
100
600
261
228
3.68
801
Program 5
−−
.035 309L Stainless Steel
−−
Recommended Gases: 98 Argon/2 CO
2
Alternative Gases: Argon/CO
2
mixes up to 10% CO
2
;
Argon/O
2
mixes up to 5% O
2
IPM
Trim
Peak Amp
Background Amp
Freq.
Pulse Width
Starting Amps
100
0
272
40
44
1.52
402
165
10
298
49
77
1.67
420
230
20
310
72
88
1.79
441
295
30
322
96
100
1.91
458
360
40
334
108
112
2.03
480
425
50
348
115
125
2.14
494
490
60
362
122
138
2.22
501
555
70
374
129
151
2.29
508
620
80
388
136
164
2.35
515
685
90
400
143
177
2.40
522
750
100
411
150
190
2.45
529
Содержание Invision 456MP
Страница 4: ......
Страница 14: ...OM 193 267 Page 10...
Страница 30: ...OM 193 267 Page 26 4 8 How Manual Pulsed MIG Waveform Components Affect Arc and Burn Off Rate...
Страница 45: ...OM 193 267 Page 41 193 264 A...
Страница 46: ...OM 193 267 Page 42 Figure 7 2 Circuit Diagram For Welding Power Source 575 Volt Models...