OM-193 267 Page 36
6-3. Removing Right Side Panel and Measuring Input Capacitor Voltage in 230/460 Volt
Models
Turn Off welding power source, and
disconnect input power.
1
Right Side Panel
To remove panel, remove screws
securing panel to unit.
2
Relinking Board PC6
3
Voltmeter
Measure the dc voltage across the
screw terminals on PC6 as shown
until voltage drops to near 0 (zero)
volts.
Proceed with job inside unit. Rein-
stall right side panel when finished.
Tools Needed:
5/16 in
802 314 / Ref. 802 315
1
!
Significant DC voltage can remain on capacitors af-
ter unit is Off. Always check the voltage as shown
to be sure the input capacitors have discharged be-
fore working on unit.
2
2
3
3
230 VAC input:
+ lead to lower
terminal,
−
lead to
upper terminal
460 VAC input:
+ lead to lower right
terminal,
−
lead to
upper left terminal
Содержание Invision 456MP
Страница 4: ......
Страница 14: ...OM 193 267 Page 10...
Страница 30: ...OM 193 267 Page 26 4 8 How Manual Pulsed MIG Waveform Components Affect Arc and Burn Off Rate...
Страница 45: ...OM 193 267 Page 41 193 264 A...
Страница 46: ...OM 193 267 Page 42 Figure 7 2 Circuit Diagram For Welding Power Source 575 Volt Models...