A complete Parts List is available at www.MillerWelds.com
OM-234 163 Page 19
4-14. Wiring Optional 240 Volt Plug (119 172) For Connection To Miller Bobcat, Trailblazer
Or Hobart Champion 10,000
Ref. 120 813-D / Ref. 805 161-A
1
Input And Grounding
Conductors
2
Plug Wired for 240 V, 2-Wire
Load
3
Neutral (Brass) Terminal And
Prong
(Not Used)
4
Load 1 (Brass)Terminal And
Prong
5
Load 2 (Brass) Terminal And
Prong
6
Ground (Brass) Terminal And
Prong
7
Black And White Input
Conductors
8
Green Or Green/Yellow
Ground Conductor
!
Always connect green or
green/yellow wire to ground
terminal, never to a load
terminal. Connect black (L1)
and white (L2) wires to load
terminals.