OM-1500-13 Page 19
5-4. Trigger Hold Switch
1
Trigger Hold Switches
Trigger hold allows the operator to
weld without holding the gun trigger.
•
To use the trigger hold function,
place the trigger hold switch in
the On position.
•
The operator must hold the trig-
ger for a minimum of 2 seconds,
but not longer than 6 seconds be-
fore releasing it. Welding will con-
tinue when the trigger is re-
leased.
•
To stop welding, press the trigger
again.
1
Ref. 803 184
5-5. Voltage Control And Digital Meters
3
1
2
1
Voltmeter
Displays actual or preset voltage
from welding power source through
the 14
−
pin control cable.
2
Wire Speed Meter
Displays preset and actual wire
feed speed while welding.
Factory set to display inches per
minute. If display of meters per min-
ute is desired, see Section 4-13.
3
Voltage Controls
Use controls to adjust voltage out-
put of welding power source.
.
You can adjust the preset volt-
age display on the wire feeder
to match your power source’s
display by adjusting P2 on mo-
tor control board PC101 (left
side), and/or P2 on motor con-
trol board PC1 (right side).
Ref. 803 183
Содержание DS-74D12 Swingarc
Страница 4: ......
Страница 27: ...OM 1500 13 Page 23 Notes...
Страница 28: ...OM 1500 13 Page 24 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram...
Страница 29: ...OM 1500 13 Page 25 204 716 B...
Страница 40: ...Notes...
Страница 41: ...Notes...
Страница 42: ...Notes...