17
Parametric Information
Discovery R (ohms):
display resistance value.
Port Current (mA):
display current value.
Port Voltage (V):
display voltage value.
Port Power (W):
display watt value.
Class Current (mA):
display class current value. When you enable the “Bypass
classification” function, the class current value will not show in here. Please refer to
the following table for output value.
Class
Usage
Maximum power of levels at
output of PSE
0 Default
15.4
Watts
1 Optional
4.0
Watts
2 Optional
7.0
Watts
3 Optional
15.4
Watts
4
Reserved for future use
Treat as Class 0
Determined Class:
display power class. When you enable the “Bypass
classification” function, the class value will not be shown.
Figure 4-6. Parametric Information interface