14
Port Specific Control
Port Enable:
enabling the port. This function is co-responding with “Master Enable”
function.
Bypass Detection:
bypass the detection function. Normally the system will try to
detect the 25k
Ω
resistor in an 802.3af compliant PD device. If the PD doesn’t follow
by IEEE 802.3af standard, you can enable this option to skip the detection on PD.
When you enable this function, the system will not perform the 25
Ω
resistor
detection for PD and directly transmit the power to PD. This function can be
cooperating with “PD discover R (ohms)” function in System setup & Control section
for non-standard compliant PD device.
[Note]
after setting the Bypass Detection function, please unplug and then plug in
the PD device.
Bypass Classification:
the system will skip the power classification and directly
transmit the power to PD when this function is enabling. Normally the system will try
to classify the 802.3af compliant PD device by checking the current class level. The
following table is a standard current classification level table.
Note:
After setting the Bypass Classification function, please unplug and then plug in
the PD device.
Power Device
Power (W)
Classification Current
(mA)
Class
Usage
MIN MAX MIN MAX
0 Default
0.44
12.95
0
4
1 Optional
0.44
3.84
9
12
2 Optional
3.84
6.49
17
20
3 Optional
6.49
12.95
26
30
4
Optional
Reserved for future use
36
44
Table of Power Device Classification Levels
Содержание MIL-L800i
Страница 1: ...MIL L800i 8 Port Power over Ethernet Injector Hub USER GUIDE...
Страница 11: ...8 5 Click the button to start installation See Figure 3 2 Figure 3 2...
Страница 19: ...16 Figure 4 5 Port Specific Control interface...
Страница 25: ...90000429 Rev 1P...