background image

 

 

 

 

 

 

 

 

 

 

 

MIL-L800i 

8-Port Power over Ethernet Injector Hub 

 

 

 

 

USER GUIDE

 

Содержание MIL-L800i

Страница 1: ...MIL L800i 8 Port Power over Ethernet Injector Hub USER GUIDE...

Страница 2: ...onsumer or purchaser and is not assignable MiLAN Technology makes no express or implied warranties including but not limited to any implied warranty of merchantability or fitness for a particular purp...

Страница 3: ...ED Indicators 4 Rear Panel 4 Power On 5 Network Application 5 3 Software Utility Installation 7 4 GUI Management 10 Connecting to PoE 10 System Setup Control 11 System Information 12 Device Setting 13...

Страница 4: ...d pairs of wires in a Category 5 cable The MIL L800i complies with the IEEE 802 3af standard and is completely compatible with existing industry standard Ethernet switches and networked devices Since...

Страница 5: ...fety short circuit protection to prevent cable short Supports IEEE 802 3af non standard device and supports manual detection of PD Auto refresh port status and support Plug and Play feature for PD Pac...

Страница 6: ...verview Physical Dimensions The MIL L800i PoE Injector Hub s physical dimension is 440mm x 224mm x 44mm Lx W x H Front Panel The Front Panel of the MIL L800i PoE Injector Hub consists of 16x RJ 45 Eth...

Страница 7: ...ansmitting to the device Power Forwarding Off Power is not transmitting to the device On Orange Device is overload or short Blinking Orange It is detecting the PD Power Off Off No device attached Tabl...

Страница 8: ...e if power is properly supplied Network Application The Power over Ethernet Hub can provides power to the PD that follow the IEEE 802 3af standard in the network It can solve the problem of position l...

Страница 9: ...5x 7x 1x C 1 2 3 4 5 6 7 8 91011 12 A B 12x 6x 8x 2x 9x 3x 10x 4x 11x 5x 7x 1x Ethernet A 12x 6x 8x 2x 9x 3x 10x 4x 11x 5x 7x 1x C POWERFAULT DATA ALARM Core Switch Switch Power over Ethernet Hub PC...

Страница 10: ...informations The software utility provides GUI interface and user can easily to start with it The software utility supports Windows environment Window 98 2000 and XP Please follow the below steps to i...

Страница 11: ...8 5 Click the button to start installation See Figure 3 2 Figure 3 2...

Страница 12: ...button to finish See Figure 3 3 Figure 3 3 7 To run the software utility go to Star Program Power Over Ethernet series 8 If you want to remove the software utility go to Star Control Panel Remove Add...

Страница 13: ...utility and select the COM port form Serial Link Setup function You will see the main utility interface as figure 4 1 Figure 4 1 The GUI management interface The GUI management is divided into three p...

Страница 14: ...controlling please remove the PD device and enable this function to calibrate internal system PD Discovery R ohms set the PD resistor value range for the system detecting The default value range is 19...

Страница 15: ...set version and revision information Firmware Version display the system firmware version Utility Version display the system utility version Total Port Power W total of all the port power that the sys...

Страница 16: ...h in every 2 seconds Load from Device To get the last configuration value from device to the system utility Save to Device When you have configured the System Setup Control and Port Specific Control p...

Страница 17: ...rd compliant PD device Note after setting the Bypass Detection function please unplug and then plug in the PD device Bypass Classification the system will skip the power classification and directly tr...

Страница 18: ...s following Null It means there is no PD connected or the connected PD device status is normal Overload It means the current is over the PD current classification limited 475mA 48V DC that the situati...

Страница 19: ...16 Figure 4 5 Port Specific Control interface...

Страница 20: ...ion function the class current value will not show in here Please refer to the following table for output value Class Usage Maximum power of levels at output of PSE 0 Default 15 4 Watts 1 Optional 4 0...

Страница 21: ...system 125Watts maximum Management Microsoft windows based application for power management Power over Ethernet mode Mid Spain Management utility Support Microsoft windows based application for power...

Страница 22: ...istor detected value current voltage power consumption classification current and determined class LED System power Per port power Forwarding power off Power AC 100 240V 50 60 Hz 130 Watts IEC power s...

Страница 23: ...used to connect to the switch for out of band console configuration The web interface configuration program can be accessed from PC running the system utility program The pin assignments used to conn...

Страница 24: ...B 104 RxD Received Data 2 2 BA 103 TxD Transmitted Data 3 3 AB 102 SGND Signal Ground 5 5 NOTE Remaining pins are not used Console Port to 9 Pin DTE Port on PC Switch s 9 Pin Serial Port CCITT Signal...

Страница 25: ...90000429 Rev 1P...