background image

Product Features

Front panel

The MIL-FT240TX has three 10/100Base-T(x) ports.

Auto-Negotiation

(selectable)

The Auto-Negotiation feature automatically configures the transceiver to achieve
the best possible mode of operation over a link. The transceiver broadcasts its speed

(10 Mb/s or 100 Mb/s) 

and duplex capabilities 

(full or half) 

to the other devices and

negotiates the best mode of operation. Auto-Negotiation allows quick and easy
installation because the optimal link is established automatically—no user
intervention required. 
In a scenario where the media converter is linked to a non-negotiating device, the
user may want to disable Auto-Negotiation. In this instance, the mode of operation
will drop to the least common denominator between the two devices 

(e.g., 10 Mbs,

half-duplex).

Disabling this feature gives the user the ability to force the connection

to the desired speed and duplex mode.

Data Transfer rate 

(selectable)

10Base-T data transfer rate:  10 Mbps baseband Ethernet 
100Base-TX data transfer rate:  100 Mbps baseband Ethernet 

Full-Duplex network 

(selectable)

In a full-duplex network, maximum cable lengths are determined by the type of
cables used. The 512-Bit Rule does not apply in a full-duplex network.

Half-Duplex network 

(selectable) (512-Bit Rule) 

In a half-duplex network, the maximum cable lengths are determined by the round
trip delay limitations of each fast Ethernet collision domain. 

(A collision domain is

the longest path between any two terminal devices, e.g., terminal, switch, or router.) 

The 512-Bit Rule determines the maximum length of cable permitted by calculating
the round-trip delay in bit times (BT) of a particular collision domain. If the result is
less than or equal to 512 BT, the path is good. 

AutoCross™

When the AutoCross feature is activated, it allows either straight-through MDI or
crossover MDI-X cables to be used when connecting to 10Base-T or 100Base-TX
devices. AutoCross determines the characteristics of the connection and
automatically configures the unit to link up, regardless if the cable configuration is
MDI or MDI-X. This feature is ON permanently.

2

PWR

Primary

Backup

Main

Primary

Backup

10/100Base-TX

10/100Base-TX

10/100Base-TX

MIL-FT240TX

Technical Support:  1.800.466.4526. Press "2" --  International: 1.408.744.2751

Installation

CAUTION: Do Not install the  MIL-FT240TX transceiver in location where it might be
exposed to wetness. Failure to observe this caution could result in damage to the
transceiver.

Set DIP Switch

Four (4) Dip Switches
• SW 1:  Auto-Negotiation 
• SW 2:  Speed
• SW 3:  Duplex
• SW 4:  Not Used

Note

: See the diagrams below and use a very small flatblade screwdriver or similar

device to set the DIP switch.

When Auto-Negotiation is enabled 

(switch #1 UP)

, the transceiver

advertises all rate and mode capabilities to the network: 100Mb/s full
duplex, 100Mb/s half-duplex, 10Mb/s full duplex, and 10Mb/s half
duplex. 

Note:

Switches “#3” and “#4” are  non-functional when switch “#1” is in the UP
position 

(Auto-Negotiation enabled).

When auto-negotiation is disabled 

(switch #1 DOWN)

, the transceiver

does not advertise rate and mode capabilities to the network. 

100Base-TX data transfer rate 

(switch #2 UP)

: 100 Mbps fast

Ethernet. 

1

3 4

2

Up

1

3 4

2

Down

1

3 4

2

Up

MIL-FT240TX

Email:  [email protected]

Side View

RJ-45 Ports

4 DIP Switches

Содержание MIL-FT240TX

Страница 1: ...the signal is present the main and primary ports will connect and the signal from the backup port is disabled Any device connected to the backup port will not detect a signal at this time However if...

Страница 2: ...ines the maximum length of cable permitted by calculating the round trip delay in bit times BT of a particular collision domain If the result is less than or equal to 512 BT the path is good AutoCross...

Страница 3: ...cording to network conditions RJ 45 Port Transceiver RJ 45 Port Switch Workstation etc 5 MIL FT240TX Installation continued Connecting power to the media converter AC DC 1 Connect the barrel connector...

Страница 4: ...Technical Support 1 800 466 4526 Press 2 International 1 408 744 2751 Crossover Cable 1 2 3 6 Straight Through Cable Twisted Pair 1 Twisted Pair 1 Twisted Pair 2 Twisted Pair 2 1 2 3 6 1 2 3 6 1 2 3...

Страница 5: ...e 0 10 000 feet Warranty 5 year limited Troubleshooting continued 6 Is there an RJ 45 cable inserted into the backup port on the transceiver NO a Insert the RJ 45 cable into the transceiver backup por...

Страница 6: ...likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Clas...

Страница 7: ...of their respective owners Copyright restrictions 2004 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or me...

Отзывы: