The DLM-080 FUTURE Digital Recorder – User’s Manual
26.11.2004
45
1 – while time-meter is counting
and Tini contact opens, counting
will be stopped. Closing the contact
again will result in continuation of
time metering. In case if time-
meter reaches set value, after
opening Tini contact the time-meter
will be reset to zero. Closing the
contact again will make the time-
meter start counting.
2 – if Tini contact opens, time-
meter will be reset to zero. Closing
the contact again will make the
time-meter start counting.
025Dh F63
0..2
Procedure of operation for CHANNEL 2
defined as time-meter (F39)
as before
025Eh F64
0..2
Procedure of operation for CHANNEL 3
defined as time-meter (F40)
as before
025Fh F65
0..2
Procedure of operation for CHANNEL 4
defined as time-meter (F41)
as before
0260h F66
0..2
Procedure of operation for CHANNEL 5
defined as time-meter (F42)
as before
0261h F67
0..2
Procedure of operation for CHANNEL 6
defined as time-meter (F43)
as before
0262h F68
0..2
Procedure of operation for CHANNEL 7
defined as time-meter (F44)
as before
0263h F69
0..2
Procedure of operation for CHANNEL 8
defined as time-meter (F45)
as before
0264h F70
0..255
Allowable difference between set value and
read out value for channel 1. Alarm will
indicate cases, when this difference is
exceeded.
0265h F71
0..255
Allowable difference between set value and
read out value for channel 2. Alarm will
indicate cases, when this difference is
exceeded.
0266h F72
0..255
Allowable difference between set value and
read out value for channel 3. Alarm will
indicate cases, when this difference is
exceeded.
0267h F73
0..255
Allowable difference between set value and
read out value for channel 4. Alarm will
indicate cases, when this difference is
exceeded.
0268h F74
0..255
Allowable difference between set value and
read out value for channel 5. Alarm will
indicate cases, when this difference is
exceeded.
0269h F75
0..255
Allowable difference between set value and
read out value for channel 6. Alarm will
indicate cases, when this difference is
exceeded.
026Ah F76
0..255
Allowable difference between set value and
read out value for channel 7. Alarm will