Tag the boiler “DO NOT USE- SYSTEM DRAINED” and remove the fuse at the isolating
switch.
37. User Instructions
37.1 Annual Servicing.
It is a condition of the boiler warranty that all servicing and maintenance be carried out
annually by Mikrofill approved engineers only.
When the word [INSPECTION] is displayed in the LCD display on the control panel, a full
service of the unit is required.
A service has to be carried out when:
The status display appears INSPECTION
or
Every 12 months
37.2 Decommissioning the boiler.
When decommissioning the boiler, precautions should be taken to avoid frost damage.
Therefore it is essential that both the boiler and the central heating system are
completely drained down.
37.3
Built-in clock
the appliance has a unique built-in three
channel programmable time clock. This enables not only the setting of the heating times
for various temperatures, but also the heating times for hot water. During programmed
off periods Combi models will maintain a minimum storage temperature
of 40
o
C. For H
and HS type appliances connected to hot water cylinder for this function to operate
temperature control has to be provided with a sensor (available from Mikrofill). When hot
water temperature control is provided by a cylinder thermostat this function is not
available. For convenience it is possible to ignore the built in programmer and
alternatively control the boiler using a remote programmer. Please check with your
installer to confirm which option has been installed.