The Ethos 29cc is designed for 230 ~ 240v 50Hz single phase operation. The method of
connection to the mains supply should allow for complete electrical isolation of the boiler,
preferably by labelled double pole switched spur. The boiler must be protected by a 3
amp fuse. The point of connection to the mains should be readily accessible and
adjacent to the boiler. If the boiler is to be sited in a bathroom the connection should be
outside the room.
It is essential that the electrical supply in the property should be properly earthed in
accordance with current IEE Wiring Regulations.
Using 3 core 1.5mm
2
cable connect the boiler to the mains electrical supply by passing
the cable through the cable duct and connecting to the Wieland connector as shown in
figure 28.
22. Heating Control Options
There are various methods of controlling the heating system from the boiler.
Using a regular room thermostat.
If a room thermostat is installed there must not be any thermostatic radiator valves on
the radiator in that room.
Using a modulating room stat
With this special type of room thermostat, the boiler can be regulated in a modulating
fashion. Please contact the Mikrofill technical department for more information.
If a room unit is installed there must not be any thermostatic radiator valves on the
radiator in that room.
Using the built-in weather compensating control
This only requires an outside temperature sensor. (
Mounted on North facing wall
)
The integral boiler weather compensating controller is adjusted so the relationship
between the outside temperature and the boilers flow temperature is sufficient to
maintain the building temperature.