![MIKOM 147362 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/mikom/147362/147362_user-manual_1793933060.webp)
User’s manual for Remote Unit MOR701B Power
M0069A0A.doc
Id.-No 151154
Page 60
23-June-99
figure 9-4 Position of RAM/RTC battery
F
Note:
Before replacing the battery, disconnect the Repeater from mains.
Observe the rules for changing Lithium batteries. Wrong connection or
treatment may result in bursting of the battery and dissemination of
hazardous substances.
Don’t try to charge this battery.
9.6 Replacement of the dummy battery backup module
The dummy battery backup module is accessible after opening the housing on the left-hand
side.
Before you are able to remove the module from the socket, release the three snap-in lockings.
RAM/RTC battery
dummy battery backup module