2.5 Duplexer
The task of the duplexer is to isolate uplink from downlink, i.e. isolate transmit path from
receive path. The pass bandwidth of the duplexer is the entire width of the uplink band and
the downlink band.
Two frequency - dependent versions of the MOR701B Power are available:
Id - No
UL frequency
DL frequency
147362
1850 - 1885 MHz
1930 - 1965 MHz
148669
1875 - 1910 MHz
1955 - 1990 MHz
figure 2-5 Top view of the duplexer
RF probe
30 dB
Duplexer