![MIKOM 147362 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/mikom/147362/147362_user-manual_1793933039.webp)
User’s manual for Remote Unit MOR701B Power
M0069A0A.doc
Id.-No 151154
Page 39
23-June-99
5.5 External electrical interfaces
5.5.1
Electrical power
The Repeater MOR701B Power can be supplied with the following power supplies (mains):
•
115 Vac
±
15% 40 - 65 Hz
•
230 V ac
±
15% 40 - 65 Hz
•
185 - 320 Vac 40 - 65 Hz
•
24 Vdc
•
±
42 to
±
60 Vdc
•
±
80 to
±
130 Vdc
A firmly installed mains cable is used, which is fed into the housing through a watertight
cable gland. Due to safety reasons the power supply lead has to be protected by two 8 A fuses.
Inside the Repeater, mains are connected to a screw terminal.
See figure 5-1 Screw terminal for mains cable for the position of the two 8 A fuses.
figure 5-1 Screw terminal for mains cable