5 Specification
5.1 Electrical specification
Frequency range
UL: 1850 - 1885 MHz; DL: 1930 - 1965 MHz
UL: 1875 - 1910 MHz; DL: 1955 - 1990 MHz
Useable bandwidth
35 MHz in the upper or lower PCS1900 band
Gain
65 dB
Gain variation over
frequency and temperature*
±2.5 dB (±3.5 dB at extreme temperatures)
Gain adjust range
30 dB in 2 dB steps
Gain adjust range tolerance
±0.5 dB
Return loss
15 dB @ 25°C ambient temperature
Spurious/intermodulation
-13 dBm max
Spectral re-growth (CDMA only)
-45 dBc (J-STD-008)
Power supply
115 VAC
±
15% / 40 - 65 Hz
Option:
230 VAC
±
15% / 40 - 65 Hz
Option:
185 - 320 VAC / 40 - 65 Hz
Option:
24 VDC
Option:
42 to 60 VDC
RF connector
7/16 female
Option:
N female
Environmental and safety
See separate leaflet