![MIHM-VOGT 7203000100 Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/mihm-vogt/7203000100/7203000100_operating-manual_1793739087.webp)
Faults and error messages
Version 2.5en - 12/2020
MV-R 100
Page 41
Overview of error codes
Error
Category
Cause
Measures
F10
Control system
GS1 defective
Service/dealer
F1000
Control system
SD card defective
Service/dealer
F1010
Control system
Battery defective
Service/dealer
F20
Mains voltage
Mains supply interrupted
Check mains supply
F2010
Mains voltage
Mains supply fault
Check mains supply
F30
Heating circuit
GS1 defective
(no current flow in power
unit)
Service/dealer
F32
Heating circuit
GS1 defective
(power unit error message)
Service/dealer
F40
Thermal sensors Temperature sensor S
short circuit
Service/dealer
F41
Thermal sensors Temperature sensor S
sensor break
Service/dealer
F42
Thermal sensors Thermal sensor on circuit
board defective
Service/dealer
F400
Thermal sensors Temperature sensor K
short circuit
Service/dealer
F401
Thermal sensors Temperature sensor S
sensor break
Service/dealer
F50
Cooling
Cooling system defective
Service/dealer
F500
Cooling
Fan defective
Service/dealer
F60
Drive
Door drive, door cannot be
positioned
Service/dealer
F61
Drive
Door drive, lower limit
switch defective
Service/dealer
F62
Drive
Door drive, upper limit
switch defective
Service/dealer
F70
Process
temperature
Temperature error
Usability of the sintered product,
check power supply
F71
Process
temperature
Maximum temperature
above 1680°C emergency
shut-off
Service/dealer
F700
Process
temperature
Process temperature
outside tolerance
Usability of the sintered product,
check power supply
F701
Process
temperature
Final temperature not
reached
Usability of the sintered product
Содержание 7203000100
Страница 1: ...MADE IN GERMANY BETRIEBSANLEITUNG MV R OPERATING MANUAL...
Страница 2: ......
Страница 45: ......
Страница 46: ......
Страница 89: ......