MM260 Installation Instructions
5
C
1
1
1
2
2
POWER
ON OFF
SG1
ED1
K1
06
A
VR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT
- BA
TT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK
-
PGOK200
Rev. X
C
M_BLK
M_RE
D
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
GTO Inc.
Tall
aha
sse
e, F
L
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
OFF
120
AUTO CL
OSE
TIME
MIN
MAX
STALL
FORCE
3
POWER
OFF
120
AUTO CLOSE
TIME
MIN
MAX
STALL
FORCE
ON OFF
SG1
ED1
K1
06
AVR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT- BATT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200 Rev. XC
M_BLK
M_RED
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
GTO Inc. Tallahassee, FL
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
4”
S9.8874
4
POWER
OFF
120
AUTO CLOSE
TIME
MIN
MAX
STALL
FORCE
ON OFF
SG1
ED1
K1
06
AVR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT- BATT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200 Rev. XC
M_BLK
M_RED
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
GTO Inc. Tallahassee, FL
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
Correct
Wrong
Wrong
Wire
Screwed into
wire insulation
Exposed strands
of wire
OFF
POSITION
5
POWER
ON OFF
SG1
ED1
K1
06
A
VR-ISP
D1
C2
C7
C15
LED3
D15
R20
IC4
D16
D13
D14
K2
BATT
- BA
TT+
STATUS
ANT SHLD
S9.8874
EDGE
COM
LOCK+
LOCK -
PGOK200 R
ev. X
C
M_BLK
M_RE
D
VAR2
GRN
VAR3
VAR3
VAR1
VAR4
VAR5
PF1
VAR6
WHT
GTO Inc.
Tall
aha
sse
e, F
L
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
OFF
120
AUTO CL
OSE
TIME
MIN
MAX
STALL
FORCE
6
SU
RG
E P
RO
TE
CT
OR
1. KE
EP CLE
AR! G
ate may
move a
t any ti
me.
2. Do
not a
llow
childre
n to op
erate
gate
or
play
in gate
area
.
3. Thi
s gat
e is fo
r vehic
les on
ly. Ped
estria
ns
must
use a se
parate
entra
nce.
Moving Ga
te Can
Cause
Injury
Or Dea
th
WARNING
!
1
1. KE
EP C
LEAR!
Gate
may
move a
t any ti
me.
2. Do
not a
llow
childre
n to o
pera
te gate
or
play
in gat
e area
.
3. This gate
is for vehic
les on
ly. Ped
estria
ns
must
use a se
parate
entra
nce.
Moving Ga
te Can
Cause
Injury O
r Dea
th
WARNING
!
2
12 VOL
T BA
TTER
Y
1. KEEP CLE
AR! G
ate may mo
ve at a
ny tim
e.
2. Do not allow c
hildre
n to op
erate
gate or
play in g
ate ar
ea.
3. This gate is
for vehic
les on
ly. Ped
estrian
s
must us
e a se
parate
entra
nce.
Moving Ga
te Can
Cause
Injury O
r Dea
th
WARNING
!
3
12 VOL
T BA
TTER
Y
4
12 VOL
T BA
TTER
Y
1. KEEP CLE
AR! G
ate may mo
ve at a
ny tim
e.
2. Do not allow c
hildre
n to op
erate
gate or
play in gate
area.
3. This gate is
for vehic
les on
ly. Ped
estrian
s
must us
e a se
parate
entra
nce.
Moving Ga
te Can
Cause
Injury O
r Dea
th
WARNING
!
5
Top View
Min 3 Ft
Max 1,000 Ft
GTO Transformer
Mounts Here
6
Plug in transformer to power outlet. (Use of a surge protector is
highly recommended. If outdoors use weatherproof box.)
TRANSFORMER WIRING INSTALLATION
Strip 1/2” off 2 wires and twist ends. Attach wires to trans-
former screw terminals.
With the Control Panel OFF, remove control
panel cover by unscrewing center cover fastener.
Feed 4” of low voltage wire through strain relief into box with
battery wire harness.
Insert RED and BLACK wires into CHGR terminals interchange-
ably as shown.
Attach cover back onto the control box.
WARNING
Before digging contact local authorities to locate underground utilities such as electric and gas service.
NOTE: If using a solar panel charging kit, go to page 6.