SETTING CLOSED LIMIT POSITION
With gate in the open position, (arm retracted) turn the
control box ON/OFF switch to the off position. Press and hold
the transmitter while sliding the ON/OFF switch to the ON
position and you will hear a series of beeps a pause then a
single beep. At that point release the the transmitter button.
This process may take 8 - 10 seconds.
Press and hold transmitter; gate should start closing. Release
transmitter button when gate reaches desired CLOSED position.
NOTE: If your gate stops and reverses before it fully closes, you
may need to increase the stall force. (See page 9)
Press and hold transmitter again; gate should start opening.
Release transmitter button when single audible alarm sounds
indicating that gate has reached OPEN position.
Gate operator’s closed position is now set. Press and release
transmitter to close gate for normal operation.