background image

10

Connect 

#2

 wire from the 

RELAY 

OUTPUT

 terminals on the keypad to 

the 

COM

 terminal on the gate opener 

control board.

Connect 

#1

 wire from the 

RELAY OUTPUT

 terminals 

on the keypad to the 

CYCLE 

 terminal on the 

gate opener control board.

#2

#1

Control Board Connections

NOTE: 

If your control board doesn’t look like any of these diagrams, please call Technical Service at 1-800-543-1236 or 850-575-4144 for 

additional support .

Connect 

#2

 wire from 

the keypad to the 

COM

 

terminal on the gate 
opener control board.

Connect 

#1

 wire from the 

RELAY OUTPUT

 terminals 

on the keypad to the 

CYCLE 

terminal on the 

gate opener control board.

#2

#1

POWER

ON  OFF

K1

06

D1

C2

C7

C15

LED3

D15

R20

IC4

D16

D13

D14

K2

BA

TT

-       BA

TT+

EDGE

COM

LOCK+

LOCK -

M_BLK

M_RED

VAR2

GRN

VAR3

VAR3

VAR1

VAR4

VAR5

PF1

VAR6

WHT

CYCLE

EXIT

SAFETY

COM

CHGR

CHGR

RECR

GRN

BLK

RED

EXIT

SAFETY

EDGE

CY

CLE

COMMON

LINK

Connect 

#1

 wire from the 

RELAY OUTPUT

 terminals 

on the keypad to 

CYCLE

 

terminal on the gate opener 
control board.

Connect 

#2

 wire from the 

RELAY 

OUTPUT

 terminals on the keypad 

to the 

COMMMON 

terminal on 

the gate opener control board.

#1

#2

RECEIVER

COM COM

CYCLE CLOSE

SAFETY

EXIT/ OPEN

SHADOW LOOP

CLOSE EDGE

OPEN EDGE

BLK

GRN

RED

Connect the 

#1

 wire from

RELAY OUTPUT

 terminals on the 

keypad

 to the 

CYCLE

 terminal on 

the opener control board.

Connect the 

#2

 wire from 

the 

RELAY OUTPUT

 

terminals on the keypad

 to 

one of the 

COMMON

 

terminals on the opener 
control board.

#1

#2

RECEIVER

ALM

RCVR.

COM

GRN

BLK

RED

CYCLE

SAFETY

EXIT

SHADOW

OPEN EDGE

COM

CONTROL INPUTS

CLOSE EDGE

Connect 

#1

 wire from

the 

RELAY OUTPUT

 terminals on 

the keypad to 

CYCLE

 terminal on 

the gate opener control board.

Connect 

#2

 wire from the 

RELAY OUTPUT

 terminals 

on the keypad to the 

COM

 

terminal on the gate opener 
control board.

#1

#2

Connect 

#1

 wire from the 

RELAY OUTPUT

 terminals 

on the keypad to 

CYCLE

 

terminal on the gate opener 
control board.

Connect 

#2

 wire from the 

keypad to the 

COMMON

 

terminal on the gate opener 
control board.

#1

#2

V

AR5

K1

PF1

K2

B

A

T

+

K3

K4

V

AR4

V

AR3

V

AR2

V

AR1

P

W

R

.

SF

TY

.

EXIT

C

YCLE

EDGE

SENSOR

COMMON

LOCK+

LOCK–

WHT

GRN

RED

BLK

WHT

GRN

SECOND OPR.

FIRST OPR.

RED

BLK

14 

VAC OR   

SOLAR

Mighty Mule MM371, MM372, MM571, 
MM572 and TS 571 Control Boards

Mighty Mule 500 & 502 Control Boards

MM271 Control Boards

Mighty Mule 360 Control Board

MM560, MM562, MM660, PRO3000XLS Series, 
and PRO4000XLS Series Control Boards

MM262, MM362, MM462, FM202, 
PRO-SW2000XLS Series Control Boards

Содержание MM136

Страница 1: ...MM136 Wireless Gate Entry Intercom Wireless and Wired Installation Instructions...

Страница 2: ...gramming the Keypad 11 Programming Interface 11 Program New Master Code 11 Program Add New Entry Code 11 Program Add New Temporary Entry Code 11 Delete An Entry Code 11 Delete ALL Entry Codes 12 Inter...

Страница 3: ...OTE Never install the keypad portion of this unit where a person can reach through the gate to activate it or where a person can touch the gate while activating the keypad The recommended minimum dist...

Страница 4: ...change after he has made the delivery This will prevent him from being able to regain access while still allowing those to whom you gave permanent entry codes full access After entering a valid code p...

Страница 5: ...d to factory settings All codes are deleted Default master code is 1234 10 Battery Holder Use 4 AA batteries if hard wired power supply is not used If external power source is used the 4 AA batteries...

Страница 6: ...box to power the system down 2 Enter the master code or an entry code but continue pressing the last digit Any programmed code will work a Example Press 1 2 3 and then hold down 4 3 While still holdi...

Страница 7: ...you have not changed your opener s transmitter code from the factory setting see the Setting Your Personal Transmitter Code section in the gate openers manual then set the keypad DIP switches to match...

Страница 8: ...hard wired communication between the keypad and gate opener using 16 gauge AWG stranded direct burial low voltage wire part no RB509 strip the wires back 3 16 and attach the wires to the terminal blo...

Страница 9: ...switch ON Test the keypad by entering 1 2 3 4 Step 7 Program your Personal Master Code and any additional entry codes for a total of 25 entry codes you wish See Programming the Keypad section 1 2 ABC...

Страница 10: ...RECEIVER COM COM CYCLE CLOSE SAFETY EXIT OPEN SHADOW LOOP CLOSE EDGE OPEN EDGE BLK GRN RED Connect the 1 wire from RELAY OUTPUT terminals on the keypad to the CYCLE terminal on the opener control boar...

Страница 11: ...2 seconds before returning to normal operation without saving Example Key press sequence to add 3456 as a new entry code 1234 is the Master Code The round black dot is the PROGRAM button Program Add...

Страница 12: ...OGRAM button Beeper beeps 3 times to confirm that the All Entry Codes are deleted Example Key press sequence to delete all entry codes from memory 1234 is the Master Code 1 2 3 4 0 7 The round black d...

Страница 13: ...4 hours when unplugged from the transformer You can turn the unit OFF to conserve battery power but it will not receive a signal when OFF Remove the battery access cover using a small phillips head s...

Страница 14: ...t IMPORTANT Place Intercoms through the home or office with at least 10 feet between them to prevent interference RELAY OUTPUT AC DC POWER IN 1 2 3 4 5 6 7 8 9 0 ID SET RESET JUMPER ID SET button ID S...

Страница 15: ...ottom of the intercom base unit 3 Make sure the antenna to antenna distance between the keypad and the base unit is at least 30 feet 4 Reset the MASTER Intercom base unit s ID Code Batteries must be i...

Страница 16: ...g two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operationof the device Le pr sent appareil est...

Отзывы: