Mighty Mule MM136 Скачать руководство пользователя страница 15

15

Test the System

IMPORTANT: 

The Base unit and the Keypad can not be within 30 feet of each other when operating . If units are closer than 30 

feet the signal will be inconsistent as well as emit speaker feed back . Also, multiple Base units must be no closer than 10 feet 
from each other to prevent interference .
Have someone press the CALL button on the keypad at the gate . When the base unit inside the house rings, press the ANSWER 
button and talk to the person at the gate to check the connection and range . Then press the GRANT PERMISSION button and 
have the person at the gate press any key on the keypad to activate the gate .

Troubleshooting

Make sure all connections are secure and correct .
Other electronic devices in the same area may interfere with the factory ID code . If the system does not communicate at all, 
reset the intercom/keypad ID code as follows .
RESET ID: This will require two (2) people .
1 .  Open the keypad and locate the “ID SET” button above the batteries . 
2 .  Locate the “ID SET” button on the bottom of the intercom base unit . 
3 .  Make sure the “antenna-to-antenna” distance between the keypad and the base unit is at least 30 feet .
4 .  Reset the MASTER Intercom base unit’s ID Code .

Batteries must be installed and the units turned ON .
A .  Press the “ID SET” button on the Keypad until you hear a beep, then release . This erases all stored ID Codes .
B .  Press the “ID SET” button on the MASTER Intercom for approximately 2 seconds then release . You will hear ONE beep from 

the Intercom and TWO from the Keypad, which means the ID Codes are reset .

C .  Test the system by pressing the CALL button on the Keypad to see if the Intercom receives the signal .

    NOTE: If the system is now working you will need to reset any additional Intercom you have installed . See  “Adding Additional Intercoms” .

IMPORTANT:

 Base units must be no closer than 10 feet from each other to prevent interference .

RELAY

OUTPUT

AC/DC

POWER IN

1 2 3 4 5 6 7 8 9

+

0

ID SET

+

– +

+

+

RESET

JUMPER

ID SET buttons

ID SE

T

VO

LUM

E

POWE

R

O

FF

O

N

Keypad - Inside

Intercom - Bottom

If all connections are correct and the ID SET change didn’t solve the communication problem, please call our Technical 
Service Department at 1-800-543-1236 Monday - Friday 8:00 am to 7:00 p .m . (ET) .

Содержание MM136

Страница 1: ...MM136 Wireless Gate Entry Intercom Wireless and Wired Installation Instructions...

Страница 2: ...gramming the Keypad 11 Programming Interface 11 Program New Master Code 11 Program Add New Entry Code 11 Program Add New Temporary Entry Code 11 Delete An Entry Code 11 Delete ALL Entry Codes 12 Inter...

Страница 3: ...OTE Never install the keypad portion of this unit where a person can reach through the gate to activate it or where a person can touch the gate while activating the keypad The recommended minimum dist...

Страница 4: ...change after he has made the delivery This will prevent him from being able to regain access while still allowing those to whom you gave permanent entry codes full access After entering a valid code p...

Страница 5: ...d to factory settings All codes are deleted Default master code is 1234 10 Battery Holder Use 4 AA batteries if hard wired power supply is not used If external power source is used the 4 AA batteries...

Страница 6: ...box to power the system down 2 Enter the master code or an entry code but continue pressing the last digit Any programmed code will work a Example Press 1 2 3 and then hold down 4 3 While still holdi...

Страница 7: ...you have not changed your opener s transmitter code from the factory setting see the Setting Your Personal Transmitter Code section in the gate openers manual then set the keypad DIP switches to match...

Страница 8: ...hard wired communication between the keypad and gate opener using 16 gauge AWG stranded direct burial low voltage wire part no RB509 strip the wires back 3 16 and attach the wires to the terminal blo...

Страница 9: ...switch ON Test the keypad by entering 1 2 3 4 Step 7 Program your Personal Master Code and any additional entry codes for a total of 25 entry codes you wish See Programming the Keypad section 1 2 ABC...

Страница 10: ...RECEIVER COM COM CYCLE CLOSE SAFETY EXIT OPEN SHADOW LOOP CLOSE EDGE OPEN EDGE BLK GRN RED Connect the 1 wire from RELAY OUTPUT terminals on the keypad to the CYCLE terminal on the opener control boar...

Страница 11: ...2 seconds before returning to normal operation without saving Example Key press sequence to add 3456 as a new entry code 1234 is the Master Code The round black dot is the PROGRAM button Program Add...

Страница 12: ...OGRAM button Beeper beeps 3 times to confirm that the All Entry Codes are deleted Example Key press sequence to delete all entry codes from memory 1234 is the Master Code 1 2 3 4 0 7 The round black d...

Страница 13: ...4 hours when unplugged from the transformer You can turn the unit OFF to conserve battery power but it will not receive a signal when OFF Remove the battery access cover using a small phillips head s...

Страница 14: ...t IMPORTANT Place Intercoms through the home or office with at least 10 feet between them to prevent interference RELAY OUTPUT AC DC POWER IN 1 2 3 4 5 6 7 8 9 0 ID SET RESET JUMPER ID SET button ID S...

Страница 15: ...ottom of the intercom base unit 3 Make sure the antenna to antenna distance between the keypad and the base unit is at least 30 feet 4 Reset the MASTER Intercom base unit s ID Code Batteries must be i...

Страница 16: ...g two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operationof the device Le pr sent appareil est...

Отзывы: