Water connection
Cold water connection
A water faucet with
3
/
4
" threat must be
provided on-site. If none is available the
machine must be connected to a water
line by a qualified plumber.
The water pressure must be between
14.5 -145 psi (1 -10 bar). If the water
pressure is greater than 145 psi
(10 bar), a pressure reducer must be
installed. If the water pressure is below
15 psi (1 bar), there will not be enough
water available for a complete fill.
The cold water hose (blue mark) is
not
suitable for a hot water
connection.
^
Connect the cold water intake hose
(blue mark) to the cold water valve.
^
Turn on the valve(s) and check for
leaks.
The water intake hoses are
equipped with screen filters. Do not
remove these filters except for
cleaning.
Maintenance
Replace the water hoses only with
genuine Miele hoses.
Extension hoses
Extension hoses (8’ 2" or 13’ [2.5 m or
4 m]) may be obtained from Miele.
Installation
49