Dispensing liquid process chemicals
45
Filling containers
with process
chemicals
Fill the containers for process chemicals or replace them with a full
container if a corresponding message is displayed, e.g.,
Fill supply
container Dispensing system 1
.
1
2
Unlock the service cover on the machine
.
Tilt the service cover forward
, lift it up, and lift it out of its lower
brackets.
Pull out the drawer with the containers for liquid process chemicals.
Take the corresponding container out of the drawer.
Unscrew and remove the suction wand.
Fill the process container with the required process chemical or re-
place it with a new container.
Observe the color coding for the dispensing system and the suc-
tion wand to ensure that the process chemicals do not get mixed
up.
Push the suction wand into the neck of the container and screw it
into place.
Place the container in the drawer.
The suction wand must be located on the lower side of the support.
Push the drawer into the machine.