Electrical connection
71
Electrical connection
All work on the electrical
connection must be carried out by
Miele Service, a Miele-authorized
technician or a qualified electrician.
– The electrical installation must be in
compliance with current local and
national safety regulations!
– The plug connection must comply
with national regulations. (The
electrical outlet must be accessible
after the appliance has been
installed.) This therefore facilitates an
electrical safety test performed
during maintenance or service work,
for example.
– If the dishwasher is permanently
wired to the power supply, a main
switch capable of disconnecting the
dishwasher at all poles must be
installed. This switch must have a
contact gap of at least 3 mm and
must also be lockable in the neutral
position.
– If necessary, equipotential bonding
must be carried out.
– If replacing the power cable, use only
original Miele replacement parts or a
suitable cable with
core cable ends
.
– For technical data, see the data plate
or the attached wiring diagram!
The dishwasher must only be operated
with the voltage, frequency and fuse
rating shown on the
data plate
.
This machine
can be converted to a
different type of power supply
in
accordance with the conversion
diagram and wiring diagram supplied.
Converting the machine to a different
type of power supply can lead to
longer program durations, resulting in
increased energy consumption.
The values declared on the label will
only be achieved if the machine
remains in the state in which it was
delivered.
The
data plates
(with VDE test
certificate, etc.) are located at the back
of the dishwasher and along the right
edge of the open door.
The
wiring diagram
is supplied with
the machine.
The
conversion diagram
is attached to
the electrical connection base cover
panel.