Sample calculation
A
Wall pipe, with inserted grille
= 1 x 3.8 m relative pipe length
= 3.8 m
B/D 2 bends, 90° plastic waste wa-
ter pipe
= 2 x 0.8 m relative pipe length
= 1.6 m
C
0.5 m plastic waste water pipe
= 0.5 x 1 m relative pipe length
= 0.5 m
Total duct length
= 5.9 m
Because the total duct length is less
than 20 m (according to table II), a pipe
diameter of 100 mm will be sufficient.
Exhaust air outlets on the back
of the tumble dryer
Sealing the air outlets
The ducting is installed on the right- or
left-hand side of the tumble dryer's
back panel. You must seal the unused
connection with a cap.
Turn the cap to the left to remove it.
Press the cap firmly into the open air
outlet.
Dimensions of the exhaust air outlets
100
92
100
100
92
All measurements are in mm.
The distances between the machine
and the wall are recommendations to
help make it easier to carry out service
work. If installation space is limited, the
machine can also be pushed up against
the wall.