Installation information
17
The appliances are secured individually
in their niche using the supplied instal-
lation material.
If the partition wall
a
is
narrower than
6 5/16" (160 mm)
, you will need the
side panel heater from the side-by-side
installation kit to prevent condensation
from forming and any resulting damage.
If the partition wall
a
is
thicker than
6 5/16" (160 mm)
, you do not need the
side-by-side installation kit, nor the side
panel heater.
. . . without partition wall
If the appliances are to be installed next
to each other without a partition wall
between them, they will need to be
joined together with the side-by-side in-
stallation kit. In addition, you must in-
stall the side panel heater to prevent
condensation from forming and any re-
sulting damage.