Preparing the installation niche
Risk of damage and injury from
the wine conditioning unit tipping
over.
The wine conditioning unit is very
heavy and can tip forwards when the
appliance door is open.
The installation niche must be se-
cured to the wall behind it and/or
above it with several screws. Only
this can ensure that the wine condi-
tioning unit will not tip over after be-
ing installed in the installation niche.
In addition, use the provided anti-tip
brackets to secure the installation
niche.
Parts required for installation are sup-
plied with the wine conditioning unit.
The plastic bags supplied are marked
with letters for easy identification.
When performing the individual as-
sembly steps, observe the letters
specified and use the matching plas-
tic bag with the required installation
equipment.
The anti-tip brackets prevent the wine
conditioning unit from tipping.
The anti-tip brackets are also used to fix
the installation niche securely to the
surrounding walls.
Use 2 anti-tip brackets
for each in-
dividual appliance or 4 anti-tip brack-
ets for each (side-by-side) combina-
tion of 2 appliances.
Position the anti-tip brackets
on
the left and right of the niche.
Depending on the subsequent adjust-
ment of the feet, the anti-tip brackets
are positioned 84"-85 3/16" (2,134–
2,164 mm) from the floor of the niche.