Installation
*INSTALLATION*
26
Checking the building-in niche
Check the installation dimensions
(see “Installation – Building-in
dimensions”).
Check the position of the electrical
connection. The length of the
electrical connection cable is 3 m.
The electrical socket must not be
concealed behind the appliance and
must be easily accessible in an
emergency.
Check the surroundings for possible
collisions (see “Installation –
Dimensions with appliance door
open”).
Only install the refrigeration appliance
in stable, solid building-in niches,
positioned on an even and level floor.
Also check the building-in niche for
the following criteria:
- The side walls of the building-in niche
must be even.
- The surrounding walls of the building-
in niche must be at least 16 mm
thick.
- The surrounding walls must be
securely fixed to the floor or wall.
- Shortened side walls must be at least
100 mm deep.
Before installation
Before installation, remove any
accessories from the back of the
appliance.
Check the refrigeration appliance for
transport damage.
Do not install a damaged
refrigeration appliance.
Check that all parts at the back of the
appliance are unhindered.
To protect the floor during installation,
secure an off-cut of flooring or similar
material to the floor in front of the
installation area.