Press
ß
or hold pressed in, until the
required value appears in the display.
Final rinse temperature:
^
Turn the programme selector to the
STOP position
f
.
^
Press
0
as often as necessary or
hold it pressed in until "E25" (pro-
gramming level 25 = Final rinse 2)
appears in the display. Then:
^
Turn the programme selector back to
the programme which needs to be
changed. The actual value appears
in the display field after
°C
.
^
Press
ß
or hold pressed in, until the
required value appears in the display.
Note:
When using the "vario TD" programme
observe the requirements relating to the
appropriate infection prophylaxis.
Final rinse temperature holding time:
^
Turn the programme selector to the
STOP position
f
.
^
Press
0
as often as necessary or
hold it pressed in until "E26" (pro-
gramming level 26 = Final rinse 2)
appears in the display. Then:
^
Turn the programme selector back to
the programme which needs to be
changed. The actual value appears
in the display field after
min
.
^
Press
ß
or hold pressed in, until the
required value appears in the display.
Having changed a value or all values:
^
Press the
6
button. SP appears.
^
Press
6
again. The change has
been recorded.
Programming special functions
44