Climate range
The appliance is designed for use within
a certain climate range (ambient tem-
perature) and should not be used out-
side this range.
Operating in a room which is too cold
will cause the compressor to switch off
for too long, causing the temperature
inside the appliance to rise with the risk
of food deteriorating and going off.
The climate range is stated on the data
plate inside the appliance.
Climate range
Ambient room
temperature
SN
+10 to +32 °C
N
+16 to +32 °C
ST
+16 to +38 °C
T
+16 to +43 °C
A freezer from the SN climate range
can operate without any difficulties in
rooms with a cooler ambient temper-
ature (down to +5 °C).
Ventilation
If the ventilation gaps given are
not observed, the compressor will
run more frequently and for longer
periods.
This will result in increased energy
consumption and a higher operating
temperature for the compressor. This
may, in turn, cause damage to the
compressor.
It is essential to observe the ventila-
tion gaps given.
Air at the back of the appliance gets
warm. The appliance housing unit must
therefore be constructed to allow suffi-
cient space for ventilation (see “Build-
ing-in dimensions”).
– Air intake
occurs via the plinth at
the bottom of the appliance and the
air escapes at the top
at the back
of the housing unit.
– A ventilation gap of at least 40 mm
depth must be allowed for behind the
appliance for air to circulate.