Cleaning and care
37
Lift the panel into the deflector plate
and hook it in at the back.
Lift the panel upwards at the front
and press it into the locking clip.
Resetting the grease filter operating
hours counter
After cleaning, the operating hours
counter needs to be reset.
Whilst the fan is switched on, press
the operating hours control
for
approx. 3 seconds, until only
1
is
flashing.
The grease filter symbol
goes out.
If you want to clean the grease filters
before the operating hours counter has
reached its maximum:
Press the operating hours
control
for approx. 6 seconds,
until only
1
is flashing.
Charcoal filters
With recirculation mode, two charcoal
filters must be fitted in addition to the
grease filters. These are designed to
absorb cooking odours.
The charcoal filters are inserted in the
separate recirculation box (not supplied,
see “Technical data” for details of part
number to order).
When to change the charcoal filters
Replace the charcoal filters when they
no longer absorb kitchen odours
effectively, and at least every 6 months.
The operating hours counter will remind
you to replace the charcoal filters by
lighting up the charcoal filter symbol
.
Resetting the charcoal filter
operating hours counter
After changing the charcoal filters, the
operating hours counter needs to be re-
set.