Technical Information
36
CVA615 Coffee System
4.20.1
Water Intake
The Pump takes in water from the water tank. (The Pump is fitted
with a safety valve which opens at approx. 16 bar (232 psi) system
pressure. If the pressure is too high and the safety valve opens,
water is drained off via a hose to the drip tray).
4.20.2
Water Path - Coffee
The water is then pumped under pressure through the Flowmeter,
and through the Coffee Flow Through Heater. The water is then
passed through the Water Valve, into the Brew Unit.
4.20.3
Water Path - Hot water
The Pump moves water under pressure through the Flowmeter,
and through the Coffee Flow Through Heater. The water is then
passed via the Hot Water Valve to the Hot Water Outlet.
4.20.4
Water Path - Steam
The pump moves water under pressure via the Flowmeter and
through the Coffee Flow Through Heater. When the user selects
steam; the Electronic energizes the Steam Valve. Water continues
flowing through the Steam Flow Through Heater. Steam is then
dispensed from the frothing nozzle.
Содержание CVA 615
Страница 1: ... 2004 Miele TECHNICAL INFORMATION CVA615 Coffee System ...
Страница 2: ......
Страница 12: ...Technical Information 4 CVA615 Coffee System ...
Страница 14: ...Technical Information 6 CVA615 Coffee System ...
Страница 16: ...Technical Information 8 CVA615 Coffee System ...
Страница 47: ...Technical Information 39 CVA615 Coffee System 4 22 2 CPU Electronic Figure 4 24 CPU Control Electronic ...
Страница 48: ...Technical Information 40 CVA615 Coffee System ...
Страница 108: ...Technical Information 100 CVA615 Coffee System This page intentionally left blank ...
Страница 109: ...Technical Information 101 CVA615 Coffee System 6 5 Wiring Diagram ...
Страница 110: ...Technical Information 102 CVA615 Coffee System This page intentionally left blank ...