Technical Information
66
CVA615 Coffee System
5.27
Brew Unit – Manual Reset to “Home Position”
(
with brew unit not installed in appliance)
Refer to figure 5-24.
1. Press on the latch
A
; and press the funnel down
B
.
2. Push the connection piece to the far left position
C
.
3. Press "PRESS" once.
Figure 5-24:
Moving the Brew Unit to “home position”.
4. The “Home” position (Figure 5-25) after resetting the Brew Unit.
The Brew Unit can now be reinstalled into the appliance.
Figure 5-25:
Brew Unit in reset position
.