Installation
*INSTALLATION*
74
Loosen the lug and pull the plug out.
Loosen the strain relief screw
and
unlock the casing on both sides
.
Open the casing.
Remove the stopper.
Exchange the jumper
with the
connection cable of the switching
system.
Close the casing.
Tighten the strain relief screw.
Reinsert the plug.
Connecting the e-box
Connect the fan power cable and fan
control cable to the e-box and the
fan.
Connect the control unit cable to the
e-box.
The socket positions are designed in
such a way that they cannot be mixed
up.
Connect the downdraft extractor to
the mains electricity supply.
Check that the downdraft extractor
works.
Sealing the gaps
Seal the gaps between the individual
SmartLine appliances, and between
the flush-fit SmartLine appliances
and the worktop, with a silicone
sealant that is heat-resistant to at
least 160 °C.
Unsuitable sealant can damage
natural stone.
For natural stone worktops and
natural stone tiles, only use silicone
sealant that is specially formulated
for natural stone.
Please follow the manufacturer's
instructions.
Содержание CSDA 7001 FL
Страница 16: ...Overview 16 Controls and display a Downdraft extractor On Off b Numerical keybank For setting a power level ...
Страница 30: ...Installation INSTALLATION 30 Installation examples Recirculation mode Air extraction mode ...
Страница 33: ...Installation INSTALLATION 33 Worktop cut out surface mounted B 500 1 ßR 4 B 10 0 10 1 1 ...
Страница 38: ...Installation INSTALLATION 38 Air duct dimensions surface mounted worktop depth 600 mm Side view ...
Страница 40: ...Installation INSTALLATION 40 Front view ...
Страница 41: ...Installation INSTALLATION 41 View from above ...
Страница 60: ...Installation INSTALLATION 60 Air duct dimensions flush fit worktop depth 600 mm Side view ...
Страница 62: ...Installation INSTALLATION 62 Front view ...
Страница 63: ...Installation INSTALLATION 63 View from above ...
Страница 77: ......
Страница 78: ......
Страница 80: ...M Nr 11 478 760 02 en AU NZ CSDA 7001 FL ...