Installation
*INSTALLATION*
54
Installing several
SmartLine appliances
The gaps between the individual
SmartLine appliances must be sealed
with a silicone sealant that is heat-
resistant to at least 160 °C. With flush-
fit installation, the gap between the
SmartLine appliance(s) and the worktop
must also be sealed with a silicone
sealant that is heat-resistant to at least
160 °C.
After installation, the SmartLine
appliances must be easily accessible
from below, so that the bottom half of
the casing can be removed for
maintenance. If the SmartLine
appliances are not accessible from
below, the sealant must be removed so
that they can be removed.
Worktop depth
The downdraft extractor can be
installed with the connector for the air
duct on either the right or the left-hand
side.
Minimum worktop depth for
- right connector 600 mm
- left connector 665 mm
Содержание CSDA 7001 FL
Страница 16: ...Overview 16 Controls and display a Downdraft extractor On Off b Numerical keybank For setting a power level ...
Страница 30: ...Installation INSTALLATION 30 Installation examples Recirculation mode Air extraction mode ...
Страница 33: ...Installation INSTALLATION 33 Worktop cut out surface mounted B 500 1 ßR 4 B 10 0 10 1 1 ...
Страница 38: ...Installation INSTALLATION 38 Air duct dimensions surface mounted worktop depth 600 mm Side view ...
Страница 40: ...Installation INSTALLATION 40 Front view ...
Страница 41: ...Installation INSTALLATION 41 View from above ...
Страница 60: ...Installation INSTALLATION 60 Air duct dimensions flush fit worktop depth 600 mm Side view ...
Страница 62: ...Installation INSTALLATION 62 Front view ...
Страница 63: ...Installation INSTALLATION 63 View from above ...
Страница 77: ......
Страница 78: ......
Страница 80: ...M Nr 11 478 760 02 en AU NZ CSDA 7001 FL ...