Technical Information
94
G 1xxx/G 2xxx
accurately registered in the following measuring process.
A photoelectric barrier switch (infrared (IR) diode opposite a phototransistor)
acts as a turbidity sensor. Depending on the turbidity (transparency) of the
water, a certain current flows through the phototransistor. This current is
measured and processed by the electronic which then initiates the
appropriate action. If the level of turbidity passes certain thresholds, then,
depending on the soiling detected, subsequent cleaning cycles are modified
accordingly with regard to water quantity, program duration and temperature.
Figure 050-12:
Turbidity Sensor Circuit
2
Light receiver output (emitter)
3
IR LED cathode
4
Common 5V
The sensor is situated in the feed pipe to the top spray arm; see Figure 050-13,
Item 1.
Figure 050-13:
Turbidity Sensor Location
Содержание ADVANTA G 2170
Страница 1: ...TECHNICAL INFORMATION G 1xxx and G 2xxx Dishwashers All US Models 2012 Miele USA ...
Страница 43: ...Technical Information 43 G 1xxx G 2xxx 010 Casing ...
Страница 47: ...Technical Information 47 G 1xxx G 2xxx Figure 010 5 Side Hinge Retaining Screw ...
Страница 48: ...Technical Information 48 G 1xxx G 2xxx 020 Door ...
Страница 64: ...Technical Information 64 G 1xxx G 2xxx 030 Front Panel ...
Страница 68: ...Technical Information 68 G 1xxx G 2xxx 040 Inner Cabinet ...
Страница 77: ...Technical Information 77 G 1xxx G 2xxx 050 Water Paths ...
Страница 123: ...Technical Information 123 G 1xxx G 2xxx 080 Electronic Novotronic and Touchtronic Incognito Navitronic ...
Страница 220: ...Technical Information 220 G 1xxx G 2xxx 100 Fascia Panel Touchtronic Navitronic Incognito ...
Страница 226: ...Technical Information 226 G 1xxx G 2xxx 130 Cutlery Tray ...